Cobra® Exhaust Vent for Roof Ridge 
Cobra® Exhaust Vent for Roof Ridge
Effective attic ventilation is critical for a long-lasting roof! A properly balanced attic ventilation system will help to:
- Remove excess heat and moisture to protect your roof from premature deterioration
- Prevent roof rot in your attic or roof deck
- Minimize peeling and extend the life of exterior and interior paint
- Limit the growth of harmful mold
- Safeguard your attic possessions against mildew damage
- Guard against ice damming in harsh winter climates
- Possibly reduce excessive heating and air conditioning costs
Cobra® exhaust vent is a key part of the GAF-Elk Smart Choice® Roof System Solution, and has even earned the prestigious Good Housekeeping Seal.
Professional’s Best Choice
-
Greater Homeowner Satisfaction…
Low-profile design is hidden by ridge cap shingles
-
Easy To Install…
Quick, 3-step process on roof slopes between 3:12 and 20:12. No need for complicated fitting, wrapping, connectors, or end plugs
-
Nails Included…
Includes Smart Nails ™ for reliable hand installation or
1 3/4" coil nails for nail gun installation
-
Great Performance…
Provides 16.9 sq. in./linear foot (hand nail) or 14.1 sq. in./linear foot (nail gun) of net free ventilating area at the most effective location on the roof
-
More Reliable…
Will not crack or dent during shipping and installation; won’t corrode, rust, or turn brittle
-
Ridge Cap Compatible…
Works with traditional size
Texas Department of Insurance
Product Evaluation RV-19
Florida Building Code
FL197-R2
ICC-ES-ESR 1265
Homeowner’s Best Choice
-
Vents Your Attic…
Allows heat and condensation to escape at the most effective location - the ridge
-
Looks Terrific…
100% shingle-over design is virtually invisible when installed
-
Superior Protection…
Helps to prevent wood rot and extends the life of your
exterior paint
-
Safeguards Possessions…
Helps limit mildew growth caused by damp attic air
-
Energy Efficient…
May even reduce your energy bills!
-
Watertight…
Passes the 110 mph wind-driven rain test*
-
Safer…
Helps prevent problems with insects, birds, and animals in your attic
-
Peace Of Mind…
Backed by a 40-year ltd. warranty**
*Under controlled laboratory conditions
**See ltd. warranty for complete coverage and restrictions
Balanced Ventilation Requirements
Balanced ventilation requires an equal amount of intake ventilation and exhaust ventilation. GAF-Elk recommends, at a minimum, providing 1 square foot of Net Free Ventilation for every 300 square feet of attic floor space. Consult local building codes for specific ventilation requirements in your area.
- Calculate the total square footage of the attic floor area (round up to the next highest number). This number will determine the minimum total linear feet of Cobra® exhaust vent that is needed.
- Find the appropriate amount of Cobra® exhaust vent and minimum intake ventilation that corresponds to the total attic square footage.
Based on 1/300 Rule
Total Attic
Square Footage |
Recommended Length of
Cobra® Exhaust Vent (Feet)* |
Minimum Intake Ventilation
(Net Free Area in Sq. In.)* |
| 1600 |
23/28 |
389/395 |
| 1900 |
27/33 |
457/466 |
| 2200 |
32/38 |
541/536 |
| 2500 |
36/43 |
609/607 |
| 2800 |
40/48 |
676/677 |
| 3100 |
45/53 |
761/748 |
| 3400 |
49/58 |
829/818 |
*First figure pertains to Hand Nail, second figure pertains to Nail Gun.
NOTE: Always have a balanced ventilation system. In no case should the amount of exhaust ventilation at the ridge exceed the amount of soffit ventilation.